Ventilator Newport Wave E500

Ventilator Newport Wave E500
Price: £22,266.25 Ex VAT: £18,950.00
Manuf part number: MIC-E500
Description
Newport e500 Ventilator. With its Intelligent Control System for maximum patient/ventilator synchrony, easy-to-use control panel, and a touch screen graphics display monitor. Designed for simplicity of use, the e500 offers direct access to all ventilation controls along with other frequently used functions such as Inspiratory and Expiratory Hold, 3 min Oxygen, Suction Disconnect and Preset Vent Settings Special

Features
Intelligent Control System FlexCycle Flexible Pressure Support Cycling Threshold, Automatic Slope/Rise Adjustment, Automatic Leak Compensation, Dual Control Breath Management (VTPC/VTPS). Suction Disconnect Press and hold Alarm Silence for one second to enable. Suspends ventilation while delivering continuous flow after a planned disconnect. User Set Up Functions Leak Test, Circuit Compliance Compensation (calculate and enable breathing circuit compliance of flow/volume delivery), enable 90-second Slow Inflation, Altitude Compensation, Language Selection, Violation Message Log. Bias Flow Ventilator-set bias flow flushes exhaled CO2 and stabilizes temperature, humidity and baseline pressure in the patient breathing circuit. Non-invasive Ventilation Compatible with mask ventilation for continuous or short term use. O2 Calibration Automatic oxygen sensor calibration at software determined intervals. Preset Vent Settings Mode, Breath type and settings can be preset without affecting current ventilator operation.

Specifications
Intelligent Control™ System
FlexCycle™ Flexible Pressure Support Cycling Threshold, Automatic Slope/Rise Adjustment, Automatic Leak Compensation, Dual Control Breath Management (VTPC/VTPS).
Suction Disconnect
Press and hold Alarm Silence for one second to enable. Suspends ventilation while delivering continuous flow after a planned disconnect.
User Set Up Functions
Leak Test, Circuit Compliance Compensation (calculate and enable breathing circuit compliance of flow/volume delivery), enable 90-second Slow Inflation, Altitude Compensation, Language Selection, Violation Message Log.
Bias Flow
Ventilator-set bias flow flushes exhaled CO2 and stabilizes temperature, humidity and baseline pressure in the patient breathing circuit.
Non-invasive Ventilation
Compatible with mask ventilation for continuous or short term use.
O2 Calibration
Automatic oxygen sensor calibration at software determined intervals.
Preset Vent Settings
Mode, Breath type and settings can be preset without affecting current ventilator operation

 